| Sr. No. |
Key Acceptance Criteria |
Dimension |
Standard |
Method |
Note |
Observation |
Outcome |
Uploads |
|
(Level 1) Insulators 2.0003 |
| 1 |
Total Height |
430 ± 10 |
|
|
|
436
|
OK
|
|
| 2 |
Top Sand OD / Top Collar OD |
90 ± 2 |
|
|
|
89/90
|
OK
|
|
| 3 |
Top ID |
54 ± 2.5 |
|
|
|
55
|
OK
|
|
| 4 |
Top Sand Length / Top Collar Thickness |
35 ± 20/0 |
|
|
|
48/49
|
OK
|
|
| 5 |
Top to first PC Distance |
83 |
|
|
|
85
|
OK
|
|
| 6 |
Between PC Distance |
22.5 |
|
|
|
23
|
OK
|
|
| 7 |
Top Part last big pc diameter |
152 ± 8 |
|
|
|
144
|
OK
|
|
| 8 |
Bottom part first big pc diameter |
- |
|
|
|
-
|
OK
|
|
| 9 |
Stem Diameter |
86 |
|
|
|
87
|
OK
|
|
| 10 |
Small Shed Diameter |
- |
|
|
|
-
|
OK
|
|
| 11 |
Bottom Sand OD/ Bottom Collar OD |
90 ± 2 |
|
|
|
89/90
|
OK
|
|
| 12 |
Bottom ID |
54 ± 2.5 |
|
|
|
55
|
OK
|
|
| 13 |
Bottom Sand Length / Bottom Collar Thickness |
35 ± 20/0 |
|
|
|
42/43
|
OK
|
|
| 14 |
Bottom to last Pc Distance |
77 |
|
|
|
75
|
OK
|
|
| 15 |
Big PC to Big PC Distance |
270 |
|
|
|
274
|
OK
|
|
| 16 |
Top Flatness |
0.1 |
|
|
|
0.04
|
OK
|
|
| 17 |
Bottom Flatness |
0.1 |
|
|
|
0.01
|
OK
|
|
| 18 |
Top Wall Thick. (with Sand) |
18 |
|
|
|
17/18
|
OK
|
|
| 19 |
Bot. Wall Thick. (with Sand) |
18 |
|
|
|
17/17.5
|
OK
|
|
| 20 |
Last small Pc to Big PC Distance |
|
|
|
|
|
OK
|
|
| 21 |
Customer Drawing No |
|
|
|
|
OK
|
OK
|
|
| 22 |
Die Penetration Check (DPC) |
|
|
|
|
OK
|
OK
|
|
|
| Final Observation | CAPA |
OK |
OK
|